SLIO

IM 053 - PROFIBUS-DP-Slave - 053-1DP00

Inteligentny system sterowania i zdalnych wejść/wyjść

Opis produktu

IM 053 - PROFIBUS-DP-Slave - 053-1DP00

Odercode: 053-1DP00

  • DP-V0, DP-V1
  • 244 byte input and 244 byte output data
  • 244 byte parameter data
  • Various diagnostics functions
  • Integrated DC 24V power supply for power and electronic section supply of the periphery modules
  • Status LEDs
  • Up to 64 peripheral modules
  • Zasilanie
  • x Nie
  • Input Voltage
  • x Nie
  • Current Consumption
  • x Nie
  • Max. current drain at backplane bus
  • x Nie
  • Max. current drain load supply
  • x Nie
  • Current consumption from backplane bus
  • x Nie
  • Current consumption from load voltage L+ (without load)
  • x Nie
  • Power Loss
  • x Nie
  • Number of inputs (digital)
  • x Nie
  • Rated load voltage (digital)
  • x Nie
  • Current consumption from load voltage L+ (without load)
  • x Nie
  • Signal logic input (digital)
  • x Nie
  • Input characteristic curve (digital)
  • x Nie
  • Initial data size (digital)
  • x Nie
  • Number of outputs (digital)
  • x Nie
  • Rated load voltage (digital output)
  • x Nie
  • Current consumption from load voltage L+ (without load)
  • x Nie
  • Signal logic output (digital)
  • x Nie
  • Initial data size (digital)
  • x Nie
  • Number of inputs (analog)
  • x Nie
  • Rated load voltage (analog)
  • x Nie
  • Current consumption from load voltage L+ (without load)
  • x Nie
  • Voltage inputs (analog)
  • x Nie
  • Current inputs (analog)
  • x Nie
  • Resolution in bit
  • x Nie
  • Measurement principle
  • x Nie
  • Basic conversion time
  • x Nie
  • Initial data size
  • x Nie
  • Number of outputs (analog)
  • x Nie
  • Output voltage ranges
  • x Nie
  • Output current ranges
  • x Nie
  • Resolution in bit (analog)
  • x Nie
  • Conversion time (analog)
  • x Nie
  • Output data size (analog)
  • x Nie
  • Number of counters
  • x Nie
  • Counter width
  • x Nie
  • Maximum input frequency
  • x Nie
  • Maximum count frequency
  • x Nie
  • Maximum count frequency
  • x Nie
  • Maximum count frequency
  • x Nie
  • Maximum count frequency
  • x Nie
  • Number of channels
  • x Nie
  • Input voltage (rated value)
  • x Nie
  • Power stage
  • x Nie
  • PWM frequency
  • x Nie
  • Type of encoder
  • x Nie
  • Encoder frequency
  • x Nie
  • Encoder resolution (internal)
  • x Nie
  • Control type
  • x Nie
  • Terminal voltage max.
  • x Nie
  • Terminal current max.
  • x Nie
  • Total current per module, max.
  • x Nie
  • Number of clamps
  • x Nie
  • Binding of potential
  • x Nie
  • Point-to-point protocol
  • x Nie
  • Encoder Supply: Number of outputs (L+n)
  • x Nie
  • Rated output current
  • x Nie
  • Port mode
  • x Nie
  • Load memory, integrated
  • x Nie
  • Work memory, integrated
  • x Nie
  • Work memory, maximal
  • x Nie
  • Memory card slot
  • x Nie
  • Racks, max.
  • x Nie
  • Modules per rack, max.
  • x Nie
  • Fieldbus
  • x Nie
  • Connector
  • x Nie
  • Topology
  • x Nie
  • Transmission speed, max.
  • x Nie
  • Address range inputs, max.
  • x Nie
  • Address range inputs, max.
  • x Nie
  • Material
  • x Nie
  • Montaż
  • x Nie
  • Dimensions Weight
  • x Nie
  • Dimensions Height
  • x Nie
  • Dimensions Depth
  • x Nie
  • Net weight
  • x Nie
  • Gross weight
  • x Nie
  • Certifications
  • x Nie
  • Safety protocol
  • x Nie
  • Safety requirements
  • x Nie
  • Circuit monitoring
  • x Nie
  • Operating temperature Min
  • x Nie
  • Operating temperature Max
  • x Nie
Przetwarzanie... Nazwa, opis, produkt lub słowa kluczowe Pokaż _START_ – _END_ / _TOTAL_ Wszystkie wyniki Pofiltrowane od _MAX_ Wszystkie wyniki Brak wyników Brak wyników First Last Sortuj rosnąco Sortuj malejąco

Pobierz

Nazwa
IM 053 - PROFIBUS-DP-Slave - 053-1DP00
Datenblatt für SLIO Interfacemodul 053-1DP00 (PROFIBUS-DP-Slave) Data sheet | niemiecki
Data sheet niemiecki
IM 053 - PROFIBUS-DP-Slave - 053-1DP00
Datasheet for SLIO Interface module 053-1DP00 (PROFIBUS-DP-Slave) Data sheet | angielski
Data sheet angielski
IM 053-1DP00 - Interface module PROFIBUS DP
Rev. 15-06 || SLIO IM 053-1DP00 (PROFIBUS-DP-Slave) || HW: 01 | FW: V1.0.0 Technical documentation | angielski
Technical documentation angielski
IM 053-1DP00 - Interface module PROFIBUS DP
Rev. 22-30 || SLIO IM 053-1DP00 (PROFIBUS DP slave) || HW: 06 | FW: V2.0.1 Technical documentation | angielski
Technical documentation angielski
IM 053-1DP00 - Interface-Modul PROFIBUS-DP
Rev. 15-06 || SLIO IM 053-1DP00 (PROFIBUS-DP-Slave) || HW: 01 | FW: V1.0.0 Technical documentation | niemiecki
Technical documentation niemiecki
IM 053-1DP00 - Interface-Modul PROFIBUS-DP
Rev. 22-30 || SLIO IM 053-1DP00 (PROFIBUS-DP-Slave) || HW: 06 | FW: V2.0.1 Technical documentation | niemiecki
Technical documentation niemiecki
System guide - Industrial IT Security
Rev. 21-12 || Guide Industrial Security in Information Technology Technical documentation | angielski
Technical documentation angielski
Systemleitfaden - Industrielle IT-Sicherheit
Rev. 21-12 || Leitfaden Industrielle Sicherheit in der Informationstechnologie Technical documentation | niemiecki
Technical documentation niemiecki
System SLIO - Liste der Stromaufnahmen
Rev. 22-40|| SLIO Liste der Stromaufnahmen der System SLIO Module Technical documentation | niemiecki
Technical documentation niemiecki
System SLIO - List of current consumptions
Rev. 22-40 || SLIO List of the current consumptions of the System SLIO modules Technical documentation | angielski
Technical documentation angielski
System SLIO - Kompatibilitätsliste
Rev. 21-12 || SLIO System SLIO CPUs, System SLIO IMs, Taktsynchronität Technical documentation | niemiecki
Technical documentation niemiecki
System SLIO - Compatibility list
Rev. 21-12 || SLIO System SLIO CPUs, System SLIO IMs, Isochronous mode Technical documentation | angielski
Technical documentation angielski
GSD-File for 053-1DP00 and 013C/014/015-DP-Slave
Configuration files for Vipa IM053DP - PROFIBUS-DP-Slave and VIPA SLIO-CPU (DP-Slave configuration) Settings file | angielski
Settings file angielski
EU-Declaration of Conformity - SLIO
state: 03.03.2020 Certification | niemiecki, angielski
Certification niemiecki, angielski
UL SLIO
Vol1 Sec2 Certification | angielski
Certification angielski
053-1DP00 V02 00 11
Firmware for PLC System_SLIO Interface-Module Firmware files have the following name structure: Name_ax_Vyyy.zip Name = name/order number of module, e.g. CPU 315-2AG13 ax = hardware version, e.g. a1 for release 1, a2 for release 2 Vyyy ... = firmware version e.g. V3061500 for version 3.6.15 Firmware |
Firmware
UK-Declaration of Conformity - SLIO
state: 21.03.2024 Certification | angielski
Certification angielski
EU-Declaration of Conformity - SLIO
state: 21.03.2024 Certification | angielski, niemiecki
Certification angielski, niemiecki
YASKAWA Controls MTBF Technical documentation | angielski Technical documentation angielski
3D-Data SLIO IM 1xSubD
SLIO Interfacemodul 1x RS485 including Power Module ProfiBUS-DP and CANopen Slave CAD/CAE | angielski, niemiecki
CAD/CAE angielski, niemiecki
Yaskawa System Slio | ChinaRoHS Certification | Certification
SLIO Labeling Stripes
To print approximately the same labeling stripes as the original, it is best to use chromosulphate board with 300g sheet weight. Technical documentation | angielski
Technical documentation angielski
System SLIO ePLAN Macros
Rev. 17-30 EPLAN | angielski
EPLAN angielski

Powiazane przykłady